Intruder Grade Sub Systems
Systems can be split into sub-systems with different grades of equipment in area where the risk may be higher.
An example of this shown below would be a bank system, where the vault and ATM may be grade 4, but the bank reception area and teller area could be lower grades.
If a system is divided into sub-systems of different grades, then the CIE should be sited within the supervised area with the highest grade.
In grade 3 and 4 systems the CIE should remain protected at all times when setting any sub-system.
AM PIR Passive Infra Red Movement Detector, with Anti-mask capability
AM DT Dual Technology Movement Detector, with Anti-mask capability
VIB Vibration Detector
All equipment located in the bank reception area would need to be Grade 2 compliant.
All equipment located in the teller area would need to be Grade 3 compliant.
All equipment located in the vault and ATM room would need to be Grade 4 compliant.
Terminology
ACE Ancillary Control Equipment (eg Exit Terminator Switch)
PACE Portable Ancillary Control Equipment (eg Remote Keyfob)
CIE Control and Indicating Equipment (eg Alarm Panel)
WD Warning Device (eg Bell Box, Sounders, Strobes)
ATS Alarm Transmission System (Signalling System)
ARC Alarm Receiving Centre (Monitoring Station)
PS Power Supply (Power Supply for I & HAS)
Example of a Sub-System